RFS RF Signal Monitoring Panel
This connector is used to monitor radio frequencies. An RFS (Radio Frequency System) is typically used for monitoring the RF status of broadcast antenna and combiner systems. The MS Series 2 supports SNMP (simple network management protocol) communication, which enables integration with a high-level NMS (network management system).
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 6.0 (Build 0) |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device, e.g., 172.32.65.38.
SNMP Settings:
- Port number: The UDP port, by default 161.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Web Interface
The web interface is only accessible when the client machine has network access to the product.
How to Use
General Page
This page displays parameter information about the System, Forward Power, Reflected Power, and Return Loss.
Input Modules
This page displays parameter information about Analog Input Module 1 and 2 and the Analog Input Module 1 and 2 Threshold.
Antenna
This page displays parameter information about Antenna Feeder 1 and 2 as well as VSWR.
Patch Panel
This page displays parameter information about Patch Panel U-Links.