Table of Contents

RF Design FlexLink K7

This connector is used to manage RF Design FlexLink K7 family switches.

About

The RF Design FlexLink K7 is a scalable L-Band switch matrix system in a 6RU/19" rack mount design, supporting extended L-Band frequency range (850 to 2450 MHz) and Ka-Band and HTS applications. It allows various switch/routing configurations from 8:8 to 256:256 (in increments of 8) with multiple outputs per input and one input per output.

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.0.x Initial version Yes Yes
1.0.1.x [SLC Main] MatrixHelper class updated. Alarm Status and Threshold Alarm traps implemented. Changes in parameters descriptions. Yes Yes

Product Info

Range Supported Firmware Version
1.0.0.x Unknown
1.0.1.x Unknown

Installation and configuration

Creation

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.
  • Device address: The device address.
  • Bus address: Not required.

SNMP Settings:

  • IP port: The IP port of the device.
  • Get community string: The community string used when reading values from the device, by default public.
  • Set community string: The community string used when setting values on the device, by default private.

Usage

General

This page displays information about the device hardware, the Unit Status, the PSU Alarms, the Fan Alarms and the Input/Output configuration.

Input

This page contains the Inputs table, with the name of each input and related info, e.g., RF Power, Gain, Failure Alarms, Thresholds, etc.

Output

This page contains the Outputs table, with the Input Selected for each output as well as the Name of each output. It also displays RF Power, Failure Alarms, Locked, Backup Rule Status and Backup Input Selected.

Matrix

This page displays a matrix with the size determined in the input/output configuration.

In this Matrix, you can select crosspoints to define which input is connected to which output. You can also change the name of inputs and outputs by renaming the labels of the matrix.

Web Interface