Radeus Labs ACU 8200
The 8200 ACU is compatible with industry-standard drive cabinet interfaces and legacy position feedback devices such as absolute rotary optical encoders, standard single-speed brushless size-11 resolvers, and two-speed brushless size-20 resolvers.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [Obsolete] | Initial version | - | - |
| 1.0.1.x | Major Changes: - In the Targets table: Moved column Longitude from 12th position to 3rd position and Beacon Frequency from 14th to 4th. - Moved parameters "Offset Azimuth/Elevation/Polarization" from Positioner to Encoder page. - Moved parameters "Fault test Period ..." from Timing to Motion page. Fix: Ack/Unacknowledged Faults are now string parameters (this was incorrect from version 1.0.0.2 onwards). |
1.0.0.2 (the change made in version 1.0.0.3 is also present in 1.0.1.x, but in a different way) | - Displayed column order of table changed (existing custom reports may no longer work). - Layout changes may take some getting used to. However, the result is similar to the web interface. |
| 1.0.2.x [SLC Main] | Fixes: - Resolved issue preventing parameters Fault Test Period, Track Coast Time, Slew Coast Time, Bump Time, and Bump Off Time from being set. - Removed write option from offset parameters on the encoders page as they are read-only. |
1.0.1.x | - Updated minimum required version to 10.2.0 since the solution has been migrated to PackageReference and the legacy class library has been removed. |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | - |
| 1.0.1.x | - |
| 1.0.2.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
| 1.0.1.x | No | Yes | - | - |
| 1.0.2.x | No | Yes | - | - |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
Initialization
No extra configuration is needed.
Redundancy
There is no redundancy defined.
How to use
The element created with this connector consists of the data pages described below. Each page displays information about the Actual Positions of the antenna and Receiver parameters like the Receiver Signal Level.
General
This page displays general system parameters such as System Name, System Location and the Database Version.
Main View
This page contains Status information about the device
Settings
On this page, you can configure the device settings. More information is displayed on each subpage: Site, Receiver, Encoders, Limits, Motion, Timing, Options, Positioner and Targets.