Rohde Schwarz NRP
The Rohde & Schwarz NRP Power Meter provides numerous modes for measuring complex signal shapes using communication standards such as GSM, EDGE, DECT, etc.: continuous, average, burst, timeslot, timegate and scope mode.
This is a serial connector that can be used to manage the Rohde & Schwarz NRP Power Meter.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 3.0.0.x [SLC Main] | Bus address is used to select sensor. Only one sensor is displayed at a time. | - | - |
| 3.0.1.x | The range for parameter 2000 has been changed to 30 to 100. | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 3.0.0.x | 06.03.020 |
| 3.0.1.x | 06.03.020 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 3.0.0.x | No | Yes | - | - |
| 3.0.1.x | No | Yes | - | - |
Configuration
Connections
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Direct connection:
- Baudrate: 9600.
- Databits: 7.
- Stopbits: 1.
- Parity: No.
- FlowControl: No.
Interface connection:
- IP address/host: The polling IP or URL of the destination.
- Bus address: The bus address of the device (sensor number).
Initialization
No extra configuration is needed.
Redundancy
There is no redundancy defined.
How to use
Main View
The Output Level and Power Frequency are displayed on this page.
General
This page displays device-related information such as the device type, serial number, firmware, etc.
The Error List page button opens a subpage where you can click the Load List button to view the error numbers and text from the error/event queue of the R&S NRP.
Power Meter
The Output Level, Power Frequency and Resolution are displayed on this page. The power frequency and resolution can be configured.
This page contains page buttons to the following subpages:
- Normalize: Allows you to set the normalize output level parameter, which is used to normalize the alarm on the output level.
- Sensor Info: Contains information related to the sensor.