Rohde Schwarz NetCCU800 1+1
This connector is developed for devices such as the Rohde Schwarz NetCCU800 1+1. It polls general and transmitter-specific parameters.
About
This connector polls information about the Rohde Schwarz NetCCU800 1+1 in general and about its transmitters. For each transmitter, a DVE is created.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 2.0.0.x [SLC Main] | Connector review | Yes | No |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 2.0.0.x | Unknown |
Exported connectors
| Exported Connector | Description |
|---|---|
| Rohde Schwarz NetCCU800 1+1 TxA | Exported connector containing info about transmitter A |
| Rohde Schwarz NetCCU800 1+1 TxB | Exported connector containing info about transmitter B |
Installation and configuration
Creation
SNMP connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device, e.g., 10.17.250.16.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Usage - Main elements
General
This page contains general device and trap information.
DVB N+1
This page displays general DVB-specific parameters. It also contains an overview of all primary transmitters (A transmitters).
NSU and Tx Events
This page contains two tables with events concerning NSU and concerning the transmitters.
Transmitter Overview
This page displays a table with all the transmitters, including the reserve transmitter.
Web Interface
This page provides access to the web interface of the device. Note that the client machine has to be able to access the device, as otherwise it may not be possible to open the web interface.
Usage - Dynamic Virtual Elements
For each DVE, five pages are displayed, as detailed below.
Exciter Input Table
This page displays a table with all channels.
Exciter Status
This page displays RF and SFN information.
Summary Info
On this page, you can monitor summary status information for the transmitter.
Transmitter Commands
On this page, you can configure settings of the transmitter.
Transmitter Status
This page displays more detailed transmitter status information.
DataMiner Connectivity Framework
The 2.0.0.15 range of the Rohde Schwarz NetCCU800 1+1 connector supports the usage of DCF.
Connectivity for all exported connectors is managed by this connector.
DCF can also be implemented through the DataMiner DCF user interface and through DataMiner third-party connectors (for instance a manager).
Interfaces
Fixed interfaces
Physical fixed interfaces:
- Management Port: input type
Dynamic Interfaces
Physical dynamic interfaces:
For each transmitter A (DVE) in the Summary Info Tx Table A, the following interfaces are created:
- ASI 1: input type
- ASI 2: input type
- 1PPS Ref: input type
- 10MHz Ref: input type
- Inout: inout type
- Output: output type
For each transmitter B (DVE) in the Summary Info Tx Table B, the following interface is created.
- Inout: inout type
Connections
Internal Connections
- For each transmitter A, either the ASI 1 input or the ASI 2 input is connected to the inout of the transmitter A.
- The inout interface is connected to the output of the corresponding transmitter A.
External Connections
- If the transmitter A is in redundancy switchover, the ASI 1 input or ASI 2 input is connected to the inout of transmitter B.
- This inout is connected to the output of the corresponding transmitter A.