Rohde Schwarz SLx8000 N+1 DAB+
The Rohde Schwarz SLx8000 N+1 DAB+ is a low-power transmitter. It is reliable, compact and flexible and fills coverage gaps in transmitter networks.
These features make it ideal for use at small, remote transmitter sites that offer only limited space, are difficult to access and are affected by strong variations in power supply. The compact device can be used as a transmitter or retransmitter.
About
This is a transmitter controller. SNMPv1 is used to retrieve information from the device.
This connector allows you to manage both the DAB transmitter devices and the exciter itself.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | 1.47.0 |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | Rohde Schwarz SLx8000 N+1 DAB+ - Transmitter |
Installation and configuration
Creation
SNMP main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: the polling IP of the device e.g., 10.11.12.13
SNMP settings:
- Port number: the port of the connected device, by default 161.
- Get community string: the community string in order to read from the device. The default value is public.
- Set community string: the community string in order to set to the device. The default value is private.
Usage
General
This page displays system information as well as additional information on the status of the rack system.
Multiple buttons and page buttons are available:
- Restart button: Restarts the software of the transmitter control unit.
- Events page button: Opens a pop-up window with a table listing the events present on the device. For each event, the table displays the current Event State, Priority and Mask. You can set both the Event Priority and the Event Mask.
- Device Info page button: Opens a pop-up window with a table containing information on the software and hardware of each specific installed module.
- NTP Server page button: Opens a pop-up window with the NTP configuration settings for the device. Some of these settings can be modified, such as NTP Mode or NTP Sync Time Interval.
- Software Update page button: Opens a pop-up window with the software update settings for the device, such as Software Update Mode, Device Name and Device Group.
Transmitter
This page displays information regarding the transmitter status. Separate summary information for Exciter A and Exciter B is also available. The two tables displayed on this page complement each other.
There are also two page buttons:
- DVE Config: Opens a pop-up window containing the DVE Table. This table displays a list of all transmitters on the device. It is possible to Remove All entries, Remove Rows or apply the Automatic Removal option.
- Transmitter Events: Opens a pop-up window that displays the Transmitter Events Table for every transmitter. Some information is available, such as the Name, Mask and Priority.
Program
This page displays the Program Table. This table contains important values for programs. It also allows you to activate or deactivate individual programs.
Exciter
This page provides information on each of the exciters. The available parameters can be used to evaluate the status of each individual exciter. This page also contains three page buttons:
- Exciter Input: This button displays a pop-up page that provides input information, such as Channel Name, Sync State, Seamless and Preselected.
- Exciter Service Information: This button displays a pop-up page that provides service information, such as Short Label, Start Address, Protection Level and Uncoded Data Rate.
- Exciter Precorrection: This button displays a pop-up page that provides precorrection information, such as Linear Correction, User State, Factory State and Restore Current Settings.
DAB
This page displays the general DAB settings, such as Local Mode, Switch Over Mode and Channel Selection.
This page also contains two page buttons:
- Main Transmitter: Opens a pop-up window containing two tables, Main Transmitter Table and Transmitter A Table. The two tables displayed on this page complement each other.
- Reverse Transmitter: This button displays a pop-up page that provides Reverse DAB information, such as Program Present, Local Mode, Input Automatic and Warning Time Stamp.
DAB Events
This page displays the general DAB Event settings, such as Local Mode Status, Switch Over Mode Status and Channel Selection Status.
This page also contains two page buttons:
- Main Events: Opens a pop-up window containing two tables, Main Transmitter Events and Transmitter A Events. The two tables displayed on this page complement each other.
- Reverse Events: This button displays a pop-up page that provides Reverse DAB Events information, such as Program Present Status, Local Mode Status, Input Automatic Status and Warning Time Stamp Status.
DAB Priority
This page displays the general DAB Priority settings, such as Local Mode Priority, Switch Over Mode Priority and Channel Selection Priority.
This page also contains two page buttons:
- Main Priority Events: Opens a pop-up window containing two tables, Main Transmitter Priority and Transmitter A Priority. The two tables displayed on this page complement each other.
- Reverse Priority Events: This button displays a pop-up page that provides Reverse DAB Priority Events information, such as Program Present Priority, Local Mode Priority, Input Automatic Priority and Warning Time Stamp Priority.
Switch Over Unit
This page displays information on redundancy and switchover capabilities. This page allows you to configure the various parameters used to determine and trigger the switchover of the device.
Web Interface
This page opens the web interface of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.