Rohde Schwarz THR9 FM Single Drive

The Rohde Schwarz THR9 high-power FM transmitter makes terrestrial broadcasting of audio broadcast signals extremely efficient.

Liquid cooling and multiple transmitters are integrated in a single rack. The liquid-cooled transmitters deliver FM output power of up to 40 kW per rack.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x Initial version - -

Product Info

Range Supported Firmware
1.0.0.x Unknown

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.

SNMP Settings:

  • Port number: The port of the connected device, by default 161.
  • Get community string: The community string used when reading values from the device, by default public.
  • Set community string: The community string used when setting values on the device, by default private.

Initialization

No additional configuration is required.

Redundancy

No redundancy is defined in the connector.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

General

This page displays the Single Transmitter Op Mode, Local Mode, Fault State and Transmitter Control Table.

On this page, there are also the page buttons Event Priority and Event Enable. On the Event Priority page, there are the parameters Transmitter Op Mode Priority, Fault Priority, Local Mode Priority ... On the Event Enable page, there are the parameters Transmitter Op Mode Enable, Fault Enable, Local Mode Enable, etc.

Liquid Cooling State

This page displays the Liquid Cooling State Table. This table contains information about Inlet Temperature, Inlet Temperature Sensor Status, Outlet Temperature, Outlet Temperature Sensor, etc.

Liquid Cooling Notification

This page displays the Liquid Cooling Notification Table. This table contains information about the Name and the State for each liquid cooling notification.

N+1 Notifications

This page displays the N+1 Notification Table. This table contains information about the Name and the State for each N+1 notification.

Tx - Transmitters

This page displays the Transmitter Notification Table , which contains information about the Name of the Transmitter Notification. This page also displays the Tx Transmitter State Table, which contains information about the Forward and Reflected Power, Power Amplifier Efficiency, etc.

Tx - Exciter

This page displays the Exciter Notification Table, which contains information about the State of the Exciter Notification.

This page also displays the Exciter Commands Table, which contains information about the Frequency, Modulation Mode and Output Attenuation.

Tx - Input/Output

This page displays the FM Input Stage Notification Table, which contains information about the state of the FM input stage notification.

This page also displays the Output Stage Notification Table, which contains information about the state of the output stage notification.

Tx - Amplifier

This page displays the Tx Amplifier Phr901 Table, which contains information about the Power Input, Power Driver, etc.

Tx - Amplifier State

This page displays the Tx Amplifier State Table, which contains information about the Status Power, Power Out and Amplifier Stage Temperature.

UPS Info

This page displays the UPS Table.