Rohde Schwarz THV9 DAB N+1
The R&S THV9 transmitter is used for multiplexed Digital Audio Broadcasting in a Single Frequency Network (SFN). It consists of a source switch system, 2 transmitters, a group of amplifiers, a transmitter controller unit (TCU) and an antenna system.
This SNMP connector can be used to monitor and configure the Rohde Schwarz THV9 DAB N+1 transmitter.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | N/A |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | THV9 DAB N+1 - Transmitter: In range 1.0.0.x, there are two transmitters. For each transmitter, a DVE is exported. |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- IP port: The IP port of the device.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
How to use
This connector retrieves the information available in the element through SNMP communication.
When the element has started up, the parameters will be filled in. When the Transmitter B Fault is retrieved, entries will be added to the DVE Transmitters table based on the Tx Transmitter Commands table. For each transmitter available, one DVE element will be created.