Rohde Schwarz TMU9 DVBT2
The R&S TMU9 DVBT2 is a compact-size, efficient and reliable transmitter with different possible standard configurations. Power consumption ranges from 300 W to 3.0 kW for digital standards, going up to 4.75 kW for analog standards. With an efficiency of up to 30 % in normal mode, it both saves energy and reduces CO2 emissions. Built-in bandpass filters ensure short delivery times and innovative configurations, such as MultiTX or N+1 systems in a single rack.
This SNMP connector is used to monitor and configure the Rohde Schwarz TMU9 DVBT2 transmitter.
About
This connector can be used to monitor parameters of the transmitter and configure it.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.1.x | New MIB implementation. Cooling page added | No | Yes |
| 1.1.1.x [SLC Main] | Based on version 1.0.1.5 Parameter sequence changed. Analog mode parameters added. | No | Yes |
| 2.0.0.x | Branch version based on 1.0.1.x. DVE functionality added. | No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.1.x | Unknown |
| 1.1.1.x | Unknown |
| 2.0.0.x | Unknown |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- IP port: The IP port of the device.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Usage
General
This page displays general parameters related to the device, such as system information and control, software updates, device and product info, Tx common control, functions and notification, GPS, UPS, date and time configuration and options management.
DVB-T2 Status
This page contains the DVB-T2 State monitoring table and the DVB-T2 Status Notification config table. It also contains a page button that allows access to the DVB-T2 Sub State monitoring table.
DVB-T2 Setup
This page contains a set of monitoring and control tables, related to Configuration, Localization, Individual Addressing (IA), Channel, Frame Structure, Layer 1 (L1) and PLP. It also contains a subpage with the Sub Configuration and Sub Localization tables.
DVB-T2 Output
This page contains all monitoring and configuration parameters related to the output for every transmitter. These can be found in the following tables: Output Localization, Output Channel, Output Frame Structure, Output Layer 1, Output PLP, Output PAPR-TR and Output FEF. A subpage allows access to tables with additional information.
ATV Video Input (1.1.1.x)
This page contains all the tables related to the ATV video: The ATV Input Video, ATV Video State and ATV Video Config table.
ATV Audio Input (1.1.1.x)
This page contains all the table related to the ATV audio: The ATV Input Audio, ATV Audio State and ATV Audio Config table.
Cooling
This page includes all pressure- and temperature-related parameters. It allows you to monitor the inlet and outlet temperature state, the coolant pressure and temperature state and the coolant temperature configuration. In addition, the General Configuration section allows you among others to set the Cooling State to On or Off, to configure the Cooling Type, to set the Heat Exchangers per Rack and the Fans per Heat Exchanger, to enable or disable the Anti Freeze, set the Pumps Extra Flow Rate and set the Fan Max Speed.
Air Cooling State (1.1.1.x)
This page contains the Air Cooling State table.
Air Cooling Notification (1.1.1.x)
This page contains the Air Cooling Notification table.
Liquid State (1.1.1.x)
This page contains the Liquid Cooling State table.
Liquid Notification (1.1.1.x)
This page contains the Liquid Cooling Notification table.
Tx Transmitter
On this page, you can monitor the Transmitter State and both monitor and configure the Transmitter Notification and Commands.
Tx Exciter
This page is similar to the Tx Transmitter page, displaying the Exciter Notification, Commands and State.
Tx Exciter Automatic
This page contains the Tx Exciter Automatic table.
Tx Input Interfaces
This page contains a set of tables with information on all inputs, namely Notifications, IP and TS Feed, General Setup and Monitor.
Tx Input Sat
This page displays all Sat information and settings for every input, in the Tuner, LNB, CAM, IP Output, General and Extras tables.
Tx Input Automatic
This page contains the Automatic Notification and Automatic Configuration tables, which allow full control over input automatic configuration.
Tx Frequency Regulation
This page contains the Notification and Setup tables, allowing you to both monitor and configure the frequency regulation parameters. Additional information is also available in the Frequency Regulation State Table.
Tx SFN
Similar to the Tx Frequency Regulation page, this page contains the SFN Notification and Setup tables, as well as the SFN State monitoring table.
Tx Precorrection
This page contains a Notification table as well as Linear and Non-Linear Setup and State tables. It also includes the Crest Factor Reduction table for both monitoring and control.
Tx Output Stage
On this page, you can monitor and configure the Notification and Commands tables, as well as monitor the State table.
Tx Amplifier
On this page, you can configure the Notification and monitor the State and PMx tables.
Tx Presets
On this page, you can load and save presets for every transmitter.
Tx RF Sensors
This page contains the Tx RF Sensors Notification Table as well as the general Tx RF Sensors Table. The latter allows you to monitor and configure a large set of sensor-related parameters.
MTx
This page displays the MTx Notification Table. In addition, it contains all information about NPlus1, including the NPlus1 Configuration and Status monitoring, which can be accessed via page buttons.
Configuration (1.0.1.5 and 1.1.1.x)
This page displays the display key parameters that can be configured in the tables.
Traps (1.1.1.x)
This page displays the Events tables.
DVE Modules (2.0.0.x)
This page contains the DVE Table. The DVEs representing the transmitters and exciters are created with the data in this table.
Web Interface