SEE Telecom eAcsys NMS
The SEE Telecom eAcsys NMS is a management system that manages other elements that are used for Optical/RF transmission/reception. Other than that, it also monitors the state of the network element's chassis and the status of its PSU.
This connector monitors and controls an SEE Telecom eAcsys NMS management system, allowing the end user to assess Optical/RF measurements performed by the device, and to perform actions on the devices controlled by the device*.*
About
This connector uses SNMP and polls the following information every five minutes:
- Device uptime
- Transmission/reception statistics
- PSU and chassis information
- EEPROM information
In addition, the connector polls generic information every 24 hours.
Finally, this connector will export different connectors based on the retrieved data. A list can be found in the section "Exported Connectors" below.
Version Info
Range | Description | DCF Integration | Cassandra Compliant |
---|---|---|---|
1.0.0.x | Initial version. | No | No |
2.0.0.x | Dynamic Virtual elements are created for the modules available in the eACSYS Devices Table. | No | No |
Product Info
Range | Device Firmware Version |
---|---|
1.0.0.x | Compatible with eAcsys Release R_0.2.6 |
2.0.0.x | Compatible with eAcsys Release R_0.2.6 |
Exported connectors
The protocol only supports DVEs for range 2.0.0.x
Exported Connector | Description |
---|---|
SEE Telecom eAcsys NMS_X_eACSYS Dual RX US | Dual receiver information for device X. |
SEE Telecom eAcsys NMS_X_eACSYS TX DS | Transmitter information for device X. |
SEE Telecom eAcsys NMS_X_eACSYS PS 48V | Power supply information for device X. |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
- Device address: The device address, ranged between 1 and 16.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device. The default value is public.
- Set community string: The community string used when setting values on the device. The default value is private.
Usage
This connector has the following pages: General, Interfaces, Module Overview and DVE Tables.
General
On this page, the section on the left contains the following parameters:
- Name
- Type
- Configuration
- Serial Number
- Operating System
- SNMP Agent
- eAcsys Release
- Software Version
- Hardware Version
- BIOS Version
- Rack Number
- Slot Number
On the right-hand side of the page, the following parameters are displayed:
- Uptime
- Total Uptime
- Number of restarts
- Temperature
In addition, a Reboot Device button is available that can be used to reboot the device.
Interfaces
On the left-hand side of this page, the following parameters are displayed:
- IP Address
- Network Mask
- Default Gateway
On the right-hand side of the page, you can find the following parameters:
- HDO Bus IP Address
- HDO Bus Network Mask
- HDO Bus Default Gateway
- Mastering
- Master Address
- Poll Timeout
- Packet Timeout
Module Overview
This page displays the connected modules in the eAcsys Devices table. It is possible to remove missing modules using the drop-down menu Remove Missing Modules. With the Configuration... page button, the connector can be configured.
DVE Tables
This page displays information regarding every exported connector, i.e.:
- The transmitter modules
- The receiver modules
- The power supply modules
- The chassis modules - however, note that these are no longer exported.