Table of Contents

SES S.A. DAKS xLink Client

This is a smart-serial connector which receives messages from clients that are using xlink communication.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x No Firmware

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Interface connection:

    • IP address/host: any
    • IP port: 345

Initialization

No extra configuration is needed.

Redundancy

There is no redundancy defined.

How to use

The connector retrieves all the serial communication and places the responses in a table on the General page. It will also send the responses to the Tetronik DAKS connector.