SES S.A. Global Telemetry System
The SES S.A. Global Telemetry System is a system at SES S.A. that provides telemetry data of specific satellites. This connector displays the telemetry data in a table.
About
For each satellite available, one element must be created using an IP address and a specific port. Each port receives a continuous UDP stream with the relevant telemetry data of a specific satellite.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version (obsolete) | No | Yes |
| 1.0.1.x | - Added RF Out Column to the Telemetry Table - Auto clear functionality |
No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.0.x | Unknown |
| 1.0.1.x | Unknown |
Installation and configuration
Creation
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Direct connection:
- Baudrate: Baudrate specified in the manual of the device.
- Databits: Databits specified in the manual of the device.
- Stopbits: Stopbits specified in the manual of the device.
- Parity: Parity specified in the manual of the device.
- FlowControl: FlowControl specified in the manual of the device.
Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
Usage
General
The General page displays the Telemetry table, which contains the telemetry data of a single satellite.
This table contains the following columns:
Channel: Concatenation of the satellite, transponder and tube name.
DateTime: Timestamp of the last update of the channel.
Satellite: Name of the satellite.
Transponder: Name of the transponder.
Tube: Name of the tube.
Sat I/P: The satellite I/P in dBm.
Mode: The mode of the channel.
Nominal ALC: The nominal automatic level control of the channel in dBm.
Nominal FG: The nominal fixed gain of the channel in dBm.
Tube Status: The status of the tube.
High Voltage Status: The high voltage status of the channel.
DCC Status: The digital command control status of the channel.
RF Out: The radio frequency out of the channel.
RF Status: The radio frequency status of the channel.
FCA Status: The flux control attenuator of the channel.
GCA Status: The gain control attenuator of the channel.
Helix Status: The helix of the channel in mA.
Nominal ALC Mode: Mode that determines which nominal ALC value will be used to calculate the deviation (Custom/LRV).
Nominal ALC Mode: Mode that determines which nominal FG value will be used to calculate the deviation (Custom/LRV)
Custom Nominal ALC: Value for the nominal ALC defined by the user in dBm.
Custom Nominal FG: Value for the nominal FG defined by the user in dBm.
Deviation: Deviation of the channel in dBm. To calculate this value, the following values must be available:
- Mode
- Sat I/P
- Nominal ALC/FG
- Nominal ALC/FG Mode
- Custom Nominal ALC/FG