Table of Contents

SatService sat-nms FO

With this connector, you can gather and view information from the SatService sat-nms FO system and from the frames and modules connected to it.

It monitors a SatService sat-nms MNC system, but only as far as the fiber-optic links information is concerned. For each fiber-optic link frame, it will generate a DVE containing a table with modules information and power supply unit information.

About

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.0.x [Obsolete] Initial version. No Yes
1.0.1.x [SLC Main] Fault State as standalone parameter. No Yes

Product Info

Range Supported Firmware Version
1.0.0.x 3.1.676 2018-05-07
1.0.1.x 3.1.676 2018-05-07

Exported connectors

Exported Connector Description
SatService sat-nms FO - Frame Detailed frame data of linked modules (RX card, TX card, power supply units).

Installation and configuration

Creation

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the device.
  • Device address: The device address.

SNMP Settings:

  • IP port: The IP port of the device. Note that the default port used by many SatService systems is 2261 instead of 161.
  • Get community string: The community string used when reading values from the device, by default public.
  • Set community string: The community string used when setting values on the device, by default private.

Usage

General

This page displays general system information, such as the System General Name, System Version, System Fault State, System Contact, System Up Time, etc.

Frames

This page contains a table with all the Frames in the system that will generate DVEs. There is a toggle button to control the Automatic Frame DVE Removal and it is also possible to manually Remove DVEs that are no longer in the system via a button on each table row.