Sencore OmniHub 6-16
OmniHub 16 can meet all the major video delivery requirements of receiving, descrambling, encoding, multiplexing, modulation, and IP processing of signals in one unit. The Sencore OmniHub 6-16 connector monitors and provides settings for the device through SNMP in range 1.0.x.x. and HTTP in range 1.1.x.x.
About
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version. | - | - |
| 1.1.0.x | Changed from "SNMP" connection type to "HTTP" connection. | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | N/A |
| 1.1.0.x | N/A |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
| 1.1.0.x | No | Yes | - | - |
Configuration
Connections
HTTP Main connection
In range 1.1.0.x, this connector uses an HTTP connection and requires the following input during element creation:
HTTP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
- Bus address: If the proxy server has to be bypassed, specify bypassproxy.
- Number of Retries: The number of retries for HTTP commands. This should be set to "0" for write parameters to work properly.
- Timeout of a single command (ms): The time between HTTP commands. This should be set to "10000" for write parameters to work properly.
SNMP Connection
In range 1.0.0.x, this connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- SNMP Type: SNMPv2.
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
- Bus address: The bus address of the device (default: ByPassProxy).
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
Initialization
See "1.1.0.x range" below.
Redundancy
There is no redundancy defined.
Web Interface
The web interface is only accessible when the client machine has network access to the product.
How to use
SNMP Version (1.0.0.x Range)
For the 1.0.0.x branch, the Sencore OmniHub has a limited SNMP feature set. Parameters are limited to status and configuration parameters defined in a limited MIB, and SNMP traps are not supported.
Each page contains information related to the OmniHub device such as the IP inputs and outputs, which can be configured in the associated Settings table.
HTTP Version: Authentication (1.1.0.x Range)
For the range with the HTTP connection, you need to specify a username and password on the General page of the element.
Note: The device only supports a single HTTP login session, so any user currently logged into the device web interface will be disconnected every time the DataMiner element polls the device using an HTTP REST API call. Should a user need to access the web interface, all elements that are accessing the device using HTTP must be paused to prevent this issue.