Table of Contents

Snell Wilcox KudosPro Frame

This connector was designed to interface with the KudosPro and provide the features found in the RollCall Control Panel.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x 2.5D.10

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

IP Connection

This connector uses a serial connection and requires the following input during element creation:

Serial connection:

  • IP address/host: The polling IP of the device, e.g., 172.16.61.11.
  • IP Port: The IP port of the device, e.g., 2050.
  • Bus address: Fill in the unit address and port. For example, if 26.02 is filled in, this represents the unit address 0x26 and unit port 0x02.

How to use

You can find more information about the different data pages of the element below.

General

The General page provides information related to the status of the device.

Genlock

On the Genlock page, you can view and adjust source and timing parameters for channels 1 and 2.

Audio Routing

On the Audio Routing page, you can view and adjust the routing for the AES and analog outputs.

Audio Control

On the Audio Control page, you can view and adjust the unit's input and output audio handling options.

Dolby Page

On the Dolby page, you can view and adjust the unit's Dolby parameters.

Network Page

The Network page provides access to the unit's network details and setup.

When you update the IP Address, IP Gateway, IP Netmask, or IP Configuration parameters, click the Apply IP Changes button to ensure that the updated parameters are properly saved to the unit's configuration.

Front Panel Page

On the Front Panel page, you can view and adjust the front panel features such as LCD Display and Headphone parameters.

Memories

The Memories page allows you to save up to eight system-level memory setups and recall them when required.

The options Reset to Defaults and Factory Reset are also available. Use these with caution, as they will reset previously configured parameters.

Logging

The Logging page displays how the parameters will be displayed when made available to the logging device.

The Logging Config subpage allows you to configure which parameters are available to the logging device.