Table of Contents

Sonifex RB-FSx2

The Sonifex RB-FSx2 connector can be used to monitor and configure 2 different Sonifex audio failover switch devices:

  • The RB-FS42 audio switch: 4 IO channels and 2 standby channels.
  • The RB-FS82 audio switch: 8 IO channels and 2 standby channels.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version - -

Product Info

Range Supported Firmware
1.0.0.x V1.06

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Main Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP of the destination.
  • IP port: The IP port of the destination.

SNMP Settings:

  • Get community string: The community string used when reading values from the device (default: public).
  • Set community string: The community string used when setting values on the device (default: private).

Initialization

No extra configuration is needed.

Redundancy

There is no redundancy defined.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

This element created with this connector consists of the following data pages:

  • General: Displays the Device Version and the PSUs status.
  • Channels: Displays the status of the input, output and standby channels.
  • Configuration: Allows you to change the settings of the channels.