Specialty Microwave Corp 15891-502

The serial-to-digital I/O interfaces provide a RS-232C/RS-422 serial interface to control and read 96 input and output positions.

Configuration data can be retrieved by serial, Telnet, or SNMP.

About

Version Info

Range Key Features Based on System Impact
1.0.0.x [SLC Main] Initial version. - -

Product Info

Range Supported Firmware
1.0.0.x 03.7D

System Info

Range DCF Integration Cassandra Compliant Linked Components Exported Components
1.0.0.x No Yes - -

Configuration

Connections

SNMP Connection

This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:

SNMP CONNECTION:

  • IP address/host: The polling IP or URL of the destination.
  • IP port: The IP port of the destination (default: 161).

SNMP Settings:

  • Get community string: The community string used when reading values from the device (default: public).
  • Set community string: The community string used when setting values on the device (default: private).

Redundancy

There is no redundancy defined.

Web Interface

The web interface is only accessible when the client machine has network access to the product.

How to use

The General page displays the device status, as well as the status of the power supplies and HPAs.

The Switch Positions page displays all connected switches (depending on the data length) and their current position (POS 1/POS 2).

Note: Changing the switch position (HPAs) is only possible if the operation mode is set to the Remote mode.