Specialty Microwave Corp 4360A-xxx
This device is a 1:1 protection switch for HPA switching. It is a manual and automatic controller for a 1:1 high-power waveguide switching mechanism used in satellite communication earth stations.
About
This connector use a serial connection to communicate with the device.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.0.x | -- |
Installation and configuration
Creation
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Direct connection:
- Baudrate: Baudrate specified in the manual of the device, e.g., 9600.
- Databits: Databits specified in the manual of the device, e.g., 7.
- Stopbits: Stopbits specified in the manual of the device, e.g., 1.
- Parity: Parity specified in the manual of the device*.*
- FlowControl: FlowControl specified in the manual of the device*.*
Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
- Bus address: The bus address of the device. Default value: 49. Range: 33 to 127.
Usage
General
This page displays general device parameters, such as:
- Switch Position
- Switch Mode
- Remote Mode
- Summary Fail 1Status
- Summary Fail 2Status
- Power Supply 1 Status
- Power Supply 2 Status