Supermicro SuperDoctor III
The Supermicro SuperDoctor III connector is an SNMP-based connector that can be used to monitor and configure the Supermicro SuperDoctor III Monitoring Platform.
About
This connector provides a monitoring and configuration interface for the Supermicro SuperDoctor III Monitoring Platform. It allows the user to display measurement values of different Monitor Devices and to configure their measurement limits.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | No | - | - |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device, by default public.
- Set community string: The community string used when setting values on the device, by default private.
Usage
Health Info
This page displays a table listing the different Monitor Devices installed in the Supermicro SuperDoctor III Monitoring Platform.
A monitor device can be Fan, Voltage, Temperature or Status. Measurement values are shown for each device.
Measurement high limits can be configured for Temperature and Voltage devices only. Measurement low limits can be configured for Fan and Voltage devices only. The divisor can be configured for Fan devices only.
With a toggle button, you can set the monitoring state of each device to Monitored or Not Monitored.
Webpage
This page displays the webpage of the device. Note that the client machine has to be able to access the device, as otherwise it will not be possible to open the web interface.