TSL MDU12-PM
With this connector, you can monitor information on the TSL MDU12-PM device, a power management system.
About
The TSL MDU12-PM connector is used to monitor and control a TSL MDU12-PM device. It displays both general information and specific information on inputs and outputs. In addition, it allows you to configure certain settings on the device.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version, based on "SA DCM 2.0.0.36" connector. | No | Yes |
| 1.0.1.x | Connector review. | No | Yes |
Supported Firmware Versions
Features in this connector are added by request. As it is possible to disable features in the poll manager so that they are not available, the connector is backwards compatible with older firmware. Very few features are no longer supported in newer firmware versions, so the connector is generally also forwards compatible.
| Range | Supported Firmware Version |
|---|---|
| 1.0.0x | 5.10 |
| 1.0.1.x | 5.10 |
Installation and configuration
Creation
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device, e.g., 10.11.12.13.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
- Get community string: The community string used when reading values from the device. The default value is public.
- Set community string: The community string used when setting values on the device. The default value is private.
Usage
General page
This page displays the Unit Identification and Location, the Total Number of Alarms, the Equipment Temperature, the Power-on Output Sequence, the Sequential Mode Delay between Outputs and the Status of Power Inlets. In addition, on the right side of the page you can find the Voltage Floor, the Voltage Limit, the Voltage Calibration and the Voltage. Below this, the Total Current and the Current Limit are shown.
It is possible to set the Location, the Sequential Mode Delay between Outputs, the Voltage and Current parameters, and the Power-on Output Sequence. For the latter, three possible values are available: Immediate, Sequential and Delay.
I/O page
This page displays the following tables:
- Input Table: Contains information about the Input Name, the Input Alarm and the Active Polarity. Both the Input Name and the Active Polarity can be edited.
- Output Table: Displays the Output Name, the Fuse, the Output Status, the Locked status, the Delay, the Lower and Over Current, the VA, the Watts, the Current, the Power Factor and the Output Calibration. It is possible to set the Output Name, the Delay, the Lower and Over Current and the Output Calibration, as well as the Output Status.
Web Interface page
On this page, you can view the web interface of the device. However, the client machine has to be able to access the device. Otherwise, it will not be possible to open the web interface.
Notes
Both the Input Table and the Output Table are updated every 15 seconds.