Tektronix TG700
This connector monitors the nodes in the system and polls all the supported modules.
About
The connector schedules all polling so that no polling happens at the same time. Users can delete any removed module manually or select to have it removed automatically. If a response times out, the card will go in timeout. By changing the View Name indicated in the element, you can have the created DVEs added in a different parent view. Finally, there is a Control Center page, which can be used to send a query or set a parameter.
Version Info
Range | Description | DCF Integration | Cassandra Compliant |
---|---|---|---|
1.0.0.x | Virtual version | No | No |
1.0.1.x | Serial connection added | No | Yes |
Product Info
Range | Supported Firmware Version |
---|---|
1.0.0.x | 5.6 |
1.0.1.x | 5.6 |
Exported connectors
Exported Connector | Description |
---|---|
Tektronix TG700 - GPS7 | GPS module |
Tektronix TG700 - SDI7 | Video generator module |
Installation and configuration
Creation
Serial Main Connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
- Direct connection:
- Baudrate: Baudrate specified in the manual of the device.
- Databits: Databits specified in the manual of the device.
- Stopbits: Stopbits specified in the manual of the device.
- Parity: Parity specified in the manual of the device.
- FlowControl: FlowControl specified in the manual of the device.
- Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device.
Usage
General
This table displays the Nodes Table, which lists the Name, Port, and State of each of the nodes.
GPS
This page displays the GPS Table, which allows you to manually remove a card, change the View Name or check the Overall Severity.
The page also allows you to enable or disable Auto Deletion, and contains a button that can be used to Remove All Cards from the table.
SDI
This page contains the SDI Table, which allows you to manually remove a module and change the View Name.
Chassis
This page displays the Value Tables of all the supported DVEs. These tables are the raw version of the parameters available in the created DVEs.
Control Center
On the left side of this page, you can send a query or set a value. To do so:
Select the Current Module where the query or set should be applied.
To send a query, add the Command (without a colon at the beginning; optionally concatenating multiple queries).
To set a value, fill in the Set Value parameter.
Click the Send Command button. The response will be displayed below.
The right side of the page contains buttons with common commands for general control of the system. However, be careful when you use these commands, as these can cause a complete timeout of the system.