Tektronix TG700

This connector monitors the nodes in the system and polls all the supported modules.

About

The connector schedules all polling so that no polling happens at the same time. Users can delete any removed module manually or select to have it removed automatically. If a response times out, the card will go in timeout. By changing the View Name indicated in the element, you can have the created DVEs added in a different parent view. Finally, there is a Control Center page, which can be used to send a query or set a parameter.

Version Info

Range Description DCF Integration Cassandra Compliant
1.0.0.x Virtual version No No
1.0.1.x Serial connection added No Yes

Product Info

Range Supported Firmware Version
1.0.0.x 5.6
1.0.1.x 5.6

Exported connectors

Exported Connector Description
Tektronix TG700 - GPS7 GPS module
Tektronix TG700 - SDI7 Video generator module

Installation and configuration

Creation

Serial Main Connection

This connector uses a serial connection and requires the following input during element creation:

SERIAL CONNECTION:

  • Direct connection:
    • Baudrate: Baudrate specified in the manual of the device.
    • Databits: Databits specified in the manual of the device.
    • Stopbits: Stopbits specified in the manual of the device.
    • Parity: Parity specified in the manual of the device.
    • FlowControl: FlowControl specified in the manual of the device.
  • Interface connection:
    • IP address/host: The polling IP of the device.
    • IP port: The IP port of the device.

Usage

General

This table displays the Nodes Table, which lists the Name, Port, and State of each of the nodes.

GPS

This page displays the GPS Table, which allows you to manually remove a card, change the View Name or check the Overall Severity.

The page also allows you to enable or disable Auto Deletion, and contains a button that can be used to Remove All Cards from the table.

SDI

This page contains the SDI Table, which allows you to manually remove a module and change the View Name.

Chassis

This page displays the Value Tables of all the supported DVEs. These tables are the raw version of the parameters available in the created DVEs.

Control Center

On the left side of this page, you can send a query or set a value. To do so:

  1. Select the Current Module where the query or set should be applied.

  2. To send a query, add the Command (without a colon at the beginning; optionally concatenating multiple queries).

    To set a value, fill in the Set Value parameter.

  3. Click the Send Command button. The response will be displayed below.

The right side of the page contains buttons with common commands for general control of the system. However, be careful when you use these commands, as these can cause a complete timeout of the system.