The AC8810 is a dual active output node with optical upstream segmentation. It offers a high output level (Umax 112 QAM/113.0 dBµV) and supports 1.2 GHz downstream and up to 204 MHz upstream frequencies.
This connector can be used to manually set up elements, or, when deployed with the Teleste HDM100 connector, it can be used by automatically created elements for AC8810 nodes connected to the controller.
About
Version Info
Range | Key Features | Based on | System Impact |
---|---|---|---|
1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
Range | Supported Firmware |
---|---|
1.0.0.x | 4.8.13 |
System Info
Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
---|---|---|---|---|
1.0.0.x | No | Yes | Teleste HDM100 | - |
Configuration
Connections
Serial Connection - Main
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device. Default value is 2500.
How to Use
The connector uses serial commands to request and push information to and from the node. This communication can be seen in the Stream Viewer.
The Alarm Limits, Status, and Alarms pages contain the most important parameters for monitoring.
The Spectrum and Ingress pages can be used to monitor and import real-time spectrum and ingress measurements that are being performed on the node.
Note
Changing the communication settings or device groups on the Transponder page may cause the element to go into timeout for a couple of seconds.