The Teleste CATVisor EMS is a software tool that can be used to monitor and control any product with an SNMP agent.
About
This connector uses SNMP to monitor the Teleste CATVisor EMS, mainly via trap monitoring.
Version Info
| Range | Key Features | Based on | System Impact |
|---|---|---|---|
| 1.0.0.x [SLC Main] | Initial version | - | - |
Product Info
| Range | Supported Firmware |
|---|---|
| 1.0.0.x | - |
System Info
| Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
|---|---|---|---|---|
| 1.0.0.x | No | Yes | - | - |
Installation and configuration
Creation
SNMP main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP Address/host: The polling IP of the device.
SNMP Settings:
- Port number: The port of the connected device. (Default=161)
- Get community string: The community string required to read from the device. (Default=public)
- Set community string: The community string required to set to the device. (Default=public)
Usage
General Page
This page displays two parameters:
- Server Name
- Max Alarm Duration: The maximum allowed time (in days) that an event can remain available in the Alarm Table. After this time has passed, the event will be cleared.
This page also displays the Alarm Table, which lists the received traps. The displayed columns are:
- Event Id
- Element Type
- Element Ip Address
- Element Name
- Element Location
- Event Start Time
- Severity
- Event Message
- Event Group Id
- Event Log Message Id