Thies Clima Sensor US
About
The Thies Clima Sensor US is a weather station. It captures real-time information about wind, temperature, humidity, precipitation, pressure, brightness, and system status.
Originally supporting a serial Modbus RTU implementation, the connector (from version 1.1.0.x onwards) has been refactored to use SNMP (v2c). The former Modbus-specific functionality and configuration workflow (e.g., switching device mode) have been removed. This connector now implements the SNMP interface only.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version (Serial Modbus RTU implementation) | No | Yes |
| 1.1.0.x [SLC Main] | Refactored to SNMP (v2c); removed Settings page; pruned and reordered parameters | No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.0.x | 4.11 |
| 1.1.0.x | 4.11 |
Installation and configuration
Creation
SNMP Main connection
As of version 1.1.0.x, the connector uses an SNMP (v2c) connection. Provide the following information during element creation:
SNMP CONNECTION:
- IP address/host: Device IP.
- SNMP port: Usually 161.
Configuration
No protocol mode switching is required in the SNMP version. If upgrading from a prior (Modbus) deployment, remove any legacy Modbus-specific element instances and recreate them using SNMP.
Usage
General
This page shows system and status-related parameters:
- Sensor Status (raw bitfield source)
- PSU Voltage
- General Error
- Static Error
- Used Averaging Memory
- Plausibility Check
- Heating Release
- Heating Status
The General Error, Static Error, Averaging Memory usage, Plausibility, Heating Release, and Heating Status are decoded from the sensor status byte.
Measurements
This page displays measurement groups:
- Wind: Mean Wind Speed, Wind Direction
- Humidity: Relative Humidity
- Precipitation: Precipitation Status, Precipitation Intensity, Precipitation Type
- Temperature: Air Temperature, Dew Point Temperature
- Pressure: Absolute Air Pressure, Relative Air Pressure
- Brightness: Brightness Highest Value
Settings (Range 1.0.0.x only)
In range 1.0.0.x, this page can be used for the Modbus-specific configuration and mode switching.
As of range 1.1.0.x, the Settings page is no longer available, as this configuration is no longer applicable.