Victron UPS
About
The Victron UPS is an Uninterruptible Power Supply made by Victron. This connector uses the SNMP protocol and the serial Modbus TCP protocol. The connector implements two ranges: one range is used with SNMP, the second range is used for serial Modbus.
Version Info
| Range | Description | DCF Integration | Cassandra Compliant |
|---|---|---|---|
| 1.0.0.x | Initial version (SNMP) | No | Yes |
| 1.0.1.x | Initial version (SNMP) | No | Yes |
| 2.0.0.x | Initial version (Modbus) | No | Yes |
Product Info
| Range | Supported Firmware Version |
|---|---|
| 1.0.0.x | - |
| 1.0.1.x | - |
| 2.0.0.x | Modbus TCP |
Installation and configuration
Creation
1.0.x.x.: SNMP Main connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP of the device.
SNMP Settings:
- Port number: The port of the connected device, by default 161.
2.0.0.x: Serial Main connection
This connector uses a serial connection and requires the following input during element creation:
SERIAL CONNECTION:
Interface connection:
- IP address/host: The polling IP of the device.
- IP port: The IP port of the device, by default 502.
Usage (Range 1.0.x.x)
General
This page contains general information about the device, such as the Manufacturer, Model, Software Version, etc.
Input/Output
This page displays information about the I/O of the device, including the Frequency, Voltage, Current, and Power.
Bypass/Battery
This page contains information about the battery and bypass, such as Bypass Frequency, Battery Status, Battery Temperature, etc.
Alarm Page
This page contains a table displaying all the alarms as well as settings regarding the status or accepted values.
Control
This page allows you to shut down or reboot the device with a configurable delay.
Usage (Range 2.0.0.x)
General
This is the default page of the connector. It contains all the parameters related to com.victronenergy.system, such as MAC Address, Relay State, System Battery Voltage, etc.
VE.Bus
This page contains all the parameters related to com.victronenergy.vebus, such as Input Voltage, Output Voltage, Input Current, etc.
VE.Bus Alarm
This page contains all the status and alarm parameters related to the VE.Bus page, such as Temperature Alarm, BMS Error, etc.
Battery
This page contains all the parameters related to com.victronenergy.battery, such as Battery Voltage, Current, Capacity, State of Charge, etc.
Battery Alarm
This page contains all the status and alarm parameters related to the Battery page, such as Low Voltage Alarm, High Temperature Alarm, State, etc.
Settings
This pages allows you to configure the ESS Battery Life State and ESS Minimum SoC.