Table of Contents

NT_DIAG (226)

Obtains additional information about a DMA or DMS.

string command = "QACTIONMETRICS_ELEMENT_346:125";

string[] result = (string[]) protocol.NotifyDataMiner (226 /*NT_DIAG*/ , command, null);

Parameters

  • command (string): The action that needs to be performed.

    • QACTIONMETRICS_ALL: Enables monitoring on all QActions of all elements of the DMA.
    • QACTIONMETRICS_ELEMENT_[DMA ID]:[element ID]: enables monitoring of all QActions of the specified element.
    • RESETQACTIONMETRICS_ELEMENT_[DMA ID]:[element ID]: Resets the QAction metrics of the specified element. Feature introduced in DataMiner 8.5.1 (RN 8345).
    • RESETQACTIONMETRICS_QACTION_[DMA ID]:[element ID]:[QAction ID]: Resets the QAction metrics of the specified QAction. Feature introduced in DataMiner 8.5.1 (RN 8345).
    • RESETQACTIONMETRICS_PROTOCOL_[protocol name]:[protocol version]: Resets the QAction metrics of elements running the specified version of the specified protocol. Feature introduced in DataMiner 8.5.1 (RN 8345).

    e.g. QACTIONMETRICS_ELEMENT_101:510984" (101 = DMA ID, 510984 = Element ID)

    Note

    By default, the QAction metrics are disabled. To enable monitoring, you have to enable the feature. Go to the ClientTestTool and select Advanced > Options > SLNet Options. There you can add features using a comma-separated list in 'ExtraSupportedFeatureKeys'. Refer to the documentation on the SLNetClientTestTool for more information.

Return Value

  • Depends on the command that has been sent. (E.g. for the response value of QACTIONMETRICS_ELEMENT_[DMA ID]:[element ID], refer to QAction metrics.)

Remarks

  • This method call is not commonly used in drivers. However, it can be useful to debug or monitor elements for support purposes.