64001 |
SPA_PARAM_TRACE_COMMA |
Trace |
64003 |
SPA_PARAM_FREQ_CENTER |
Center frequency (read) |
64004 |
SPA_PARAM_FREQ_SPAN |
Frequency span (read) |
64005 |
SPA_PARAM_FREQ_START |
Start frequency (read) |
64006 |
SPA_PARAM_FREQ_STOP |
Stop frequency (read) |
64008 |
SPA_PARAM_AMP_UNITS |
Amplitude units (read) |
64009 |
SPA_PARAM_INPUT_ATTEN |
Input attenuation (read) |
64010 |
SPA_PARAM_REFLEVEL |
Reference level (read) |
64011 |
SPA_PARAM_REFSCALE |
Reference scale (read) |
64012 |
SPA_PARAM_VBW |
Video bandwidth (read) AUTO=-1 |
64013 |
SPA_PARAM_FREQBW |
Freq bandwidth (read) AUTO=-1 |
64014 |
SPA_PARAM_RBW |
Resolution bandwidth (read) |
64015 |
SPA_PARAM_SWEEPTIME |
Sweep time (read) AUTO=-1 |
64016 |
SETTINGS_DONE |
|
64017 |
CLIENTCOUNT |
|
64018 |
ALLCHANGESSENT |
|
64019 |
SPA_PARAM_AUTO_VBW |
Real VBW value when VBW set to Auto (read) |
64020 |
SPA_PARAM_AUTO_RBW |
Real RBW value when RBW set to Auto (read) |
64021 |
SPA_PARAM_AUTO_SWEEP |
Real SweepTime value when sweeptime set to Auto (read) |
64022 |
SPA_PARAM_AUTO_ATTEN |
Real input attenuation when attenuation set to Auto |
64023 |
SPA_PARAM_CALIB_ERR |
Indicates if the measurement is uncalibrated (1) or not (0) (read) |
64024 |
SPA_PARAM_OFFSET_DBMV |
Difference between dbm/dbmv (0 dbm = (64024) dbmv) |
64025 |
SPA_PARAM_OFFSET_DBUV |
Difference between dbm/dbuv (0 dbm = (64025) dbuv) |
64026 |
SPA_PARAM_TRACETIMEOUT |
Specific timeout if actual trace get time >>>> 4*sweeptime |
64027 |
SPA_PARAM_UNAVAILABLE |
Set to 1 when device is doing other things (which means we should not request traces) |
64028 |
SPA_PARAM_UNAVAILABLE_REASON |
String indicating why the spectrum analyzer is unavailable |
64029 |
SPA_PARAM_PRE_AMPLIFIER |
PreAmplifier (0 = disabled / 1 = enabled) |
64030 |
SPA_PARAM_FIRST_MIXER_INPUT |
First mixer input (analog) dbm |
64031 |
SPA_PARAM_DETECTION_MODE |
Detection mode |
64032 |
SPA_PARAM_SCALE_TYPE |
Scale type (log = 0, lin = 1) |
64033 |
OBSOLETE_SPA_PARAM_NOISE_MARKER |
Noise marker function (noise marker freq) // obsolete FR458 |
64034 |
SPA_PARAM_SETTIMEOUT |
Specific "wait for 'set' to succeed" timeout (overrides the default 5s) |
64035 |
OBSOLETE_SPA_PARAM_NOISE_MARKER_RES |
Noise marker function result // obsolete FR458 |
64036 |
SPA_PARAM_OVER_RESP_NBW |
Over-response noise bandwidth (to calculate marker noise levels) |
64037 |
SPA_PARAM_AMOUNTPTS |
Number of points to expect in traces |
64038 |
SPA_PARAM_AMOUNT_HOR_DIVS |
Number of horizontal divisions (default: 10) |
64039 |
SPA_PARAM_AMOUNT_VER_DIVS |
Number of vertical divisions (default: 10) |
64040 |
SPA_PARAM_FACTOR_AUTO_VBW |
(read) Factor by which auto VBW needs to be calculated. -1 to let device handle this. |
64041 |
SPA_PARAM_FACTOR_AUTO_RBW |
(read) Factor by which auto RBW needs to be calculated. -1 to let device handle this. |
64051 |
SPA_PARAM_CONSTELLATION |
(read) Constellation points x1,x2,x3 |
64052 |
SPA_PARAM_CONST_FREQ |
(read) Input freq |
64053 |
SPA_PARAM_CONST_SYMRATE |
(read) Symbol rate |
64054 |
SPA_PARAM_CONST_MODE |
(read) QAM mode (8,16,32,64,128,256,...) |
64055 |
SPA_PARAM_CONST_IFSPECTRUM |
(read) IF spectrum |
64103 |
SPA_WPARAM_FREQ_CENTER |
Center frequency (write) |
64104 |
SPA_WPARAM_FREQ_SPAN |
Frequency span (write) |
64105 |
SPA_WPARAM_FREQ_START |
Start frequency (write) |
64106 |
SPA_WPARAM_FREQ_STOP |
Stop frequency (write) |
64108 |
SPA_WPARAM_AMP_UNITS |
Amplitude units (write) |
64109 |
SPA_WPARAM_INPUT_ATTEN |
Input attenuation (write) |
64110 |
SPA_WPARAM_REFLEVEL |
Reference level (write) |
64111 |
SPA_WPARAM_REFSCALE |
Reference scale (write) |
64112 |
SPA_WPARAM_VBW |
Video bandwidth (write) |
64113 |
SPA_WPARAM_FREQBW |
Freq bandwidth (write) |
64114 |
SPA_WPARAM_RBW |
Resolution bandwidth (write) |
64115 |
SPA_WPARAM_SWEEPTIME |
Sweep time (write) |
64116 |
SPA_WPARAM_SETTINGS_DONE |
0 (do not request trace), 1 (OK to request trace. All settings done.) |
64117 |
SPA_WPARAM_CLIENTCOUNT |
Number of data display/monitor clients |
64118 |
SPA_WPARAM_ALLCHANGESSENT |
Set to 1 after all changed parameters have been sent |
64119 - 64128 |
|
Read-only parameters |
64129 |
SPA_WPARAM_PRE_AMPLIFIER |
Pre-amplifier |
64130 |
SPA_WPARAM_FIRST_MIXER_INPUT |
First mixer input |
64131 |
SPA_WPARAM_DETECTION_MODE |
Detection mode |
64132 |
SPA_WPARAM_SCALE_TYPE |
Scale type |
64133 |
OBSOLETE_SPA_WPARAM_NOISE_MARKER |
Noise marker function // obsolete FR458 |
64137 |
SPA_WPARAM_AMOUNTPTS |
Number of points to expect in traces (write) |
64140 |
SPA_WPARAM_FACTOR_AUTO_VBW |
(write) Factor by which auto VBW needs to be calculated. -1 to let device handle this. |
64141 |
SPA_WPARAM_FACTOR_AUTO_RBW |
(write) Factor by which auto RBW needs to be calculated. -1 to let device handle this. |
64152 |
SPA_WPARAM_CONST_FREQ |
(write) Input freq |
64153 |
SPA_WPARAM_CONST_SYMRATE |
(write) Symbol rate |
64154 |
SPA_WPARAM_CONST_MODE |
(write) Mode |
64155 |
SPA_WPARAM_CONST_IFSPECTRUM |
(write) IF spectrum |
64201 |
SPA_SPARAM_MODE |
Status: mode change notifications -> element display |
64202 |
SPA_SPARAM_FROZEN |
Status: frozen state (BOOL) |
64203 |
SPA_SPARAM_RECORDING |
Status: recording state (BOOL) |
64204 |
SPA_SPARAM_PLAY_PROGRESS |
Percentage of playback completed (double) |
64205 |
SPA_SPARAM_PLAY_MANUAL |
Modified: playback state requires manual prev |
64206 |
SPA_SPARAM_PLAY_ORIGTIME |
Original time of event (String Y-m-d H:M:S) |
64207 |
SPA_SPARAM_ALARM_MARKER |
Special marker used in alarm recordings to indicate that the next trace is the one that generated the alarm (double; 1) |
64208 |
SPA_SPARAM_MEASPOINT |
Current measurement point |
64209 |
SPA_SPARAM_SCRIPTRESULTS |
In script mode: the script results (variable values; string) |
64210 |
SPA_SPARAM_TRACENAME |
Trace name (in script mode) |
64211 |
SPA_SPARAM_CLIENTCOUNT |
Real-time info on the number of connected clients |
64212 |
SPA_SPARAM_MONITOR |
Monitor info (id:estimated time). Reset to empty after monitor has run. Can also contain a full message instead of id:estimatedtime |
64213 |
SPA_SPARAM_WATCH_INFO |
Info about which data is currently being displayed (watch mode) |
64214 |
SPA_SPARAM_INVALID_PID |
Notifies Cube of a PID for which the current value is invalid |
64215 |
SPA_SPARAM_UNAVAILABLE |
Notifies Cube that the device is currently unavailable for measurements (string) |
64216 |
SPA_SPARAM_PRESET_UPDATE |
Notifies Cube that a preset got updated. Contains the name of the preset (string). |
64217 |
SPA_SPARAM_WARN_SWEEP |
Notifies Cube that it needs to display a warning to allow a sweep time > 20 sec (value = sweep time value) |
64218 |
SPA_SPARAM_GENERIC_MSG |
Notifies Cube with a generic message to display in the top-right corner (string "[message type id]:[message]") |
64219 |
SPA_SPARAM_PROGRESS |
Notifies Cube of some kind of progress (double; see SPA_PROGRESS_*) |
64220 |
SPA_SPARAM_TRACEPRESET |
Preset with which trace was taken (on playback). string. preset ID. |
64221 |
SPA_SPARAM_HAS_RT_SLOT |
0 = no more RT slots available, client will not get new traces. 1 = has slot |
64222 |
SPA_SPARAM_HEARTBEAT |
Heartbeat to indicate that the client is still known by SLSpectrum (sent every xs) |
64223 |
SPA_SPARAM_RANGES |
frequency ranges (when changed by offsets and such): startmin;startmax;centermin;centermax;stopmin;stopmax |
64224 |
SPA_SPARAM_MONITOR_PRESET |
current preset (when watching a buffer or alarm recording for a monitor which iterates over presets) |