HyperLink element

Defines a custom command that will be displayed in the shortcut menu of the Alarm Console.

Type

string

Content Type

string

Content

In the <HyperLink> tag, enter the following content, depending on the type of hyperlink specified in the type attribute (see type):

  • Type "url": The URL that should be opened.

  • Type "execute": The name of the executable file.

    The path to the executable file can include spaces, but only if it is enclosed in double quotation marks. Anything that is added after a space and is not enclosed within quotation marks will be interpreted as an argument. For example: <HyperLink id="20" version="2" type="execute" name="MyApp" menu="root" >"C:\Program Files (x86)\MyApp\App.exe" [ENAME]</HyperLink>

  • Type "script": The Automation script execution command. This should be configured in the same way as when you link a shape to an Automation script in a Visio drawing. See Linking a shape to an Automation script for more information.

    Note

    It is not necessary to use the "Script:" prefix in a second-generation hyperlink, as the type attribute already makes it clear an Automation script is referred to.

  • Type "OpenCPE": The EPM card.

    Supported from DataMiner Cube 10.4.0 [CU14]/10.5.0 [CU2]/10.5.5 onwards, or with the CPEIntegration soft-launch option in earlier DataMiner versions.

    For example, to add an "Open OLT" hyperlink to the Alarm Console context menu to open the EPM card of the object that generated the selected alarm: <HyperLink name="Open OLT" menu="root" type="OpenCPE" version="2" id="18">:visual:pagename</HyperLink>.

    Hyperlinks of this type can also be shown or hidden based on a filter configured with the filterElement attribute. For example: <HyperLink filterElement="AlarmEventMessage.PropertiesDict.&quot;System Type&quot;[String] == 'OLT'" name="Open OLT" menu="root" type="OpenCPE" version="2" id="18">[EID]:visual:qam ds</HyperLink>.

  • Type "openview": The view ID. Alternatively, you can use the [VID] placeholder to open the view of the selected alarm.

    You can also have the view opened on a particular page, using the same syntax as in a Cube argument (e.g. [VID]::Aggregation).

  • Type "openservice": The service ID. Alternatively, you can use the [SID] placeholder to open the service of the selected alarm.

    You can also have the service opened on a particular page, using the same syntax as in a Cube argument (e.g. [SID]:d:Australia Service).

  • Type "openelement": The element ID. Alternatively, you can use the [EID] placeholder to open the element of the selected alarm.

    You can also have the element opened on a particular page, using the same syntax as in a Cube argument (e.g. [EID]:Data:Performance/Ping).

  • Type "openparameter": The parameter ID. Alternatively, you can use the [PID] placeholder to open the parameter of the selected alarm.

  • Type "reference": The ID of a legacy hyperlink. See Upgrading legacy hyperlinks to second-generation hyperlinks.

Note

The string you specify can contain:

  • Keywords, which allow you to insert real-time data in the command name that is displayed.
  • Placeholders, which allow you to insert parts of the value of the alarm or information event in the command that is displayed.
Tip

See also: type

Parents

HyperLinks

Attributes

Name Type Required Description
alarmAction string Set to "acknowledge" if you want the selected alarm or alarms to be acknowledged automatically when a hyperlink is executed.
alarmColumn boolean Set to "true" if you want a hyperlink to appear not only in the Alarm Console shortcut menu but also as a column in the Alarm Console.
combineParameters boolean Set to "true" in order to combine parameters in case multiple alarms have been selected.
descriptionParsing string Specifies that the command should appear only in the shortcut menu of alarms and information events with a specific description.
filterElement string Defines a conditional hyperlink. The hyperlink will only be displayed for alarms matching the specified filter.
id integer Yes Specifies the unique identifier of the hyperlink. Used primarily for synchronization purposes.
menu string Configures where in the shortcut menu (a specific submenu or the root) the item should appear.
name string Specifies the name of the command as it has to appear in the user interfaces.
type string Yes Specifies the hyperlink type.
valueParsing string Configures the command to appear only in the shortcut menu of alarms and information events with a specific value.
version integer Yes In second-generation hyperlinks, this mandatory attribute has to be set to "2".