Table of Contents

AlarmsPerParameter element

Specifies the maximum number of alarms that can be included in an alarm tree.

Type

integer

Content Type

integer

Parents

AlarmSettings

Attributes

Name Type Required Description
client integer Specifies how many alarms in an alarm tree are saved in the Cube cache. This determines how many alarms are shown in Cube when you view the alarm tree in a new tab, when you reconnect to Cube, or when you restart the element.
recurring string Configures whether and when a notice will be generated if the number of alarms in an alarm tree exceeds the AlarmsPerParameter setting.

Remarks

If there are more alarms in an alarm tree, by default a notice will be displayed in the Alarm Console.

Note
  • SLNet limits the alarm trees in the cache and in history queries based on this tag. If no value is specified in this tag, SLNet uses a default of 20. In addition, because in old DataMiner versions the default was 100, if the value in this tag is 100, SLNet will read it as 20 instead.
  • SLDataMiner is responsible for generating notices if there are too many alarms in an alarm tree. If no value is specified in this tag, SLDataMiner uses a default of 100.

Example

<AlarmsPerParameter recurring="TRUE" client="30">60</AlarmsPerParameter>