Table of Contents

Path element

Specifies the table path that needs to be followed when passing alarm severities.

Type

TypeSemicolonSeparatedNumbers

Parent

SeverityBubbleUp

Attributes

Name Type Required Description
statePid unsignedInt Refers to a parameter that indicates whether the bubble-up path is disabled or enabled.

Remarks

The order does not need to be the same as the relation path. It depends on what table should have an effect on the other table.

Examples

In the following example,

  • the first path will cause alarm severity to bubble up from table 5000 to 4000 and up to table 3000, and
  • the second path will case alarm severity to bubble up from table 2000 to 3000.
<SeverityBubbleUp>
  <Path>5000;4000;3000</Path>
  <Path>2000;3000</Path>
</SeverityBubbleUp>