DMAAlarmTemplateParameter

Item Format Description
ID Integer The ID of the parameter.
Filter String The filter applied to the parameter, if any.
Info String The threshold defined for information messages, if any.
Hysteresis String The defined alarm hysteresis.
CL String The Critical Low alarm threshold.
MaL String The Major Low alarm threshold.
MiL String The Minor Low alarm threshold.
Normal String The Normal alarm threshold.
WaH String The Warning High alarm threshold.
MiH String The Minor High alarm threshold.
MaH String The Major High alarm threshold.
CH String The Critical High alarm threshold.
Monitored Boolean Whether the parameter is included or excluded in alarm template groups.
WaL String The Warning Low alarm threshold.
VarianceMonitor Boolean Whether alarms for variance changes are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards.
TrendMonitor Boolean Whether alarms for trend changes are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards.
LevelShiftMonitor Boolean Whether alarms for level shift anomalies are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards.
FlatlineMonitor Boolean Whether alarms for flatline anomalies are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards.
HysteresisPerSeverity DMAHysteresisInfo See DMAHysteresisInfo.
SmartBaseLine DMABaseline See DMABaseline.
DisabledIf String A condition that determines when monitoring is disabled.
AutoClear String The type of automatic clearing: False (= no autoclear), True (= autoclear) or Undef (= the system default is applied).
Type String The type of alarm thresholds: NORMAL, RELATIVE, ABSOLUTE, RATE or DISCRETE.