| ID |
Integer |
The ID of the parameter. |
| Filter |
String |
The filter applied to the parameter, if any. |
| Info |
String |
The threshold defined for information messages, if any. |
| Hysteresis |
String |
The defined alarm hysteresis. |
| CL |
String |
The Critical Low alarm threshold. |
| MaL |
String |
The Major Low alarm threshold. |
| MiL |
String |
The Minor Low alarm threshold. |
| Normal |
String |
The Normal alarm threshold. |
| WaH |
String |
The Warning High alarm threshold. |
| MiH |
String |
The Minor High alarm threshold. |
| MaH |
String |
The Major High alarm threshold. |
| CH |
String |
The Critical High alarm threshold. |
| Monitored |
Boolean |
Whether the parameter is included or excluded in alarm template groups. |
| WaL |
String |
The Warning Low alarm threshold. |
| VarianceMonitor |
Boolean |
Whether alarms for variance changes are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards. |
| TrendMonitor |
Boolean |
Whether alarms for trend changes are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards. |
| LevelShiftMonitor |
Boolean |
Whether alarms for level shift anomalies are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards. |
| FlatlineMonitor |
Boolean |
Whether alarms for flatline anomalies are enabled. Obsolete from DataMiner 10.3.12/10.4.0 onwards. |
| HysteresisPerSeverity |
DMAHysteresisInfo |
See DMAHysteresisInfo. |
| SmartBaseLine |
DMABaseline |
See DMABaseline. |
| DisabledIf |
String |
A condition that determines when monitoring is disabled. |
| AutoClear |
String |
The type of automatic clearing: False (= no autoclear), True (= autoclear) or Undef (= the system default is applied). |
| Type |
String |
The type of alarm thresholds: NORMAL, RELATIVE, ABSOLUTE, RATE or DISCRETE. |