Item Format Description
ID Integer The ID of the parameter.
ParameterName String The name of the parameter.
InfoSubText String The parameter description.
IsMonitored Boolean Whether the value of the parameter is being monitored by an alarm template.
IsNumerical Boolean Whether the value of the parameter is numerical.
HasRange Boolean Determines whether the value of the parameter is defined within a certain range.
RangeLow Double If HasRange is true, this determines the lowest value of the parameter range.
RangeHigh Double If HasRange is true, this determines the highest value of the parameter range.
RangeLowDisplay String The display value of the raw value stored in RangeLow.
RangeHighDisplay String The display value of the raw value stored in RangeHigh.
Options String The parameter options (extra flags to e.g. indicate special formatting instructions).
Unit String The unit of measure of the parameter.
PrimaryKeyID Integer If the parameter is a table parameter, the primary key.
DisplayKeyID Integer If the parameter is a table parameter, the display key.
IsLogarithmic Boolean Indicates whether the trend data of this parameter should be displayed on a logarithmic scale.
IsTableColumn Boolean Whether or not the parameter is a table column parameter.
IsTable Boolean Whether or not the parameter is a table parameter.
IsTrending Boolean Whether the value of the parameter is being trended.
TableParameterID Integer If the parameter is a column parameter, this indicates the ID of the table parameter.
Decimals Integer The number of decimals.
Type String The type of parameter: “Read”, “Write”, or “Table”.
WriteType String The type of write parameter: “String”, “Discreet”, “Number”, ...
ReadType String The type of read parameter.
Discreets Array of DMAParameterEditDiscreet The discreet values of the parameter (only if WriteType is “Discreet”).
DashboardsType String The button panel dashboard type: None, ButtonPanel, ButtonPanelContainers or ButtonPanelCollection.
Positions Array of DMAParameterPosition The places where the parameter can be found in the different Data Display pages of the element.
WarningMessage String The message that, in the protocol, can be configured on the write parameter. This message will be displayed when an attempt is made to update the parameter. For example: "Changing this setting will make the device unavailable."
AvgTrendingFilters Array of String An array of filters for which average trending is enabled (as configured in the trend template).
RealTimeTrendingFilters Array of String An array of filters for which real-time trending is enabled (as configured in the trend template).