Table of Contents

GetAlarmStateTimelineForParameter

Use this method to retrieve the alarm state timeline for a particular parameter.

Available from DataMiner version 9.5.1 onwards.

Input

Item Format Description
connection String The connection ID. See ConnectApp.
dmaID Integer The DataMiner Agent ID.
elementID Integer The element ID.
parameterID Integer The parameter ID.
tableIndex String The table index. This field must be specified for table column parameters; otherwise it must be left empty.
utcStartTime Long integer The start time of the timespan for which alarm state changes should be retrieved, in UTC format (milliseconds since midnight January 1, 1970 GMT).
utcEndTime Long integer The end time of the timespan for which alarm state changes should be retrieved, in UTC format (milliseconds since midnight January 1, 1970 GMT).
maxPoints Integer The maximum number of alarm state changes that should be returned.

Output

Item Format Description
GetAlarmStateTimelineForParameterResult DMATimeline An array of alarm state changes along with the start time and end time of the timespan in which they occur.