GetAlarmStateTimelineForParameter
Use this method to retrieve the alarm state timeline for a particular parameter.
| Item | Format | Description | 
| connection | String | The connection ID. See ConnectApp. | 
| dmaID | Integer | The DataMiner Agent ID. | 
| elementID | Integer | The element ID. | 
| parameterID | Integer | The parameter ID. | 
| tableIndex | String | The table index. This field must be specified for table column parameters; otherwise it must be left empty. | 
| utcStartTime | Long integer | The start time of the timespan for which alarm state changes should be retrieved, in UTC format (milliseconds since midnight January 1, 1970 GMT). | 
| utcEndTime | Long integer | The end time of the timespan for which alarm state changes should be retrieved, in UTC format (milliseconds since midnight January 1, 1970 GMT). | 
| maxPoints | Integer | The maximum number of alarm state changes that should be returned. | 
Output
| Item | Format | Description | 
| GetAlarmStateTimelineForParameterResult | DMATimeline | An array of alarm state changes along with the start time and end time of the timespan in which they occur. |