Validator

RTDisplay check: Additional error messages [ID 13215][ID 13855]

The RTDisplay check can now throw a number of additional errors and warnings.

Overview of all possible error and warning messages:

Result code Class Description
4400 Information RTDisplay tags OK.
4401 Error Param [Parameter ID] has an unexpected RTDisplay="true" value.
4402 Error RTDisplay="true" required on parameter [Parameter ID], which is used as dependency ID in parameter [Parameter ID].
4404 Error RTDisplay="true" required. Parameter is used as dependency value in parameter [Parameter ID].
4405 Error RTDisplay="true" required on write parameter [Parameter ID], which has a related read parameter [Parameter ID] dependency value in ContextMenu parameter [Parameter ID].
4406 Error RTDisplay="true" is required on parameter [Parameter ID], which is used in treecontrol(s) [comma-separated list of tree control IDs].
4408 Error RTDisplay="true" required on parameter [Parameter ID], which is used in a tree control ExtraTabs parameter attribute on line [Line number].
4409 Error RTDisplay="true" is required on parameter [Parameter ID], which is used in alarm option properties on parameter [Parameter ID].
4410 Error RTDisplay="true" required on parameter [Parameter ID], which is used in the pageOrder option Webinterface.
4411 Error RTDisplay="true" is required on parameter [Parameter ID], which is used as a context menu.
4412 Error RTDisplay="true" is required on parameter [Parameter ID], which is used as QAction feedback.
4413 Error RTDisplay="true" is required on parameter [Parameter ID], which has mapAlarm="true".
4414 Error RTDisplay="true" is required on parameter [Parameter ID], which is used by DMS Spectrum.
4417 Error RTDisplay="true" is required on parameter [Parameter ID], which has a virtual source defined.
4418 Error RTDisplay="true" is required on parameter [Parameter ID], which is used in Params loadSequence.
4419 Error RTDisplay="true" is required on parameter [Parameter ID], which is displayed on table [Parameter ID].
4420 Error RTDisplay="true" required. ColumnOption for table [Parameter ID] uses option [Option].
4421 Error RTDisplay="true" is required on parameter [Parameter ID], which is used in a relation.
4422 Error RTDisplay="true" is required. Parameter [Parameter ID] is an exported table.

Trend/Alarm check: Additional error messages [ID 13855]

The Trend/Alarm check can now throw the following additional warnings:

Result code Class Description
2403 Warning Parameter [Parameter ID] has trending="true", but is not displayed on any page. This is not consistent. Please verify.
2404 Warning Parameter [Parameter ID] is monitored, but is not displayed on any page. This is not consistent. Please verify.

New check: Check whether all parameter IDs in the <Measurement> tag of a table have a corresponding <ColumnOption> tag [ID 13219]

A new check has been added that will throw an error whenever the <Measurement> tag of a table contains a parameter ID that doesn’t have a corresponding <ColumnOption> tag.

Result code Class Description
1705 Error Parameter [Column parameter ID] is included in the table measurement but not in the table definition.

New check: Check whether all table parameters have a correct measurement type [ID 13220]

A new check has been added that will throw an error whenever a parameter of type “array” doesn’t have its measurement type set to either “table” or “matrix”.

Result code Class Description
1706 Error Measurement type for array is not table or matrix.

XML Schema

New units of measure [ID 13216]

The XML Schema will now accept the following additional units of measure:

Unit of measure Description
IRE Unit used in the measurement of composite video signals, derived from “Institute of Radio Engineers”
PDU Protocol Data Unit
MIB objects Number of objects in a MIB
Allocation unit Unit of disk space allocation for files and directories
Messages Number of messages
Datagrams Number of datagrams
Failures Number of failures
Fragments Number of fragments
Files Number of files
Peers Number of peers
KiB Kibibyte (1024 bytes)
MiB Mebibyte (1024 kibibytes)
GiB Gibibyte (1024 mebibytes)
TiB Tebibyte (1024 gibibytes)
Sessions Number of sessions
Requests Number of requests

Changes

Enhancements

IDE - MIB browser enhancements [ID 12972]

A number of enhancements have been made to the MIB browser:

  • Up to now, when you imported an SNMP parameter with base syntax ‘OBJECT IDENTIFIER’, DIS imported a parameter of type “numeric text/double”. From now on, DIS will import a parameter of type “other/string” instead.

  • From now on, the MIB browser will allow you to import only files with the following extensions:

    • .mib
    • .smi
    • .txt
  • It is now possible to scroll through the list of loaded, pending and missing modules.

Up to now, in some cases, the SNMP type of an imported SNMP parameter was incorrect. This has now also been fixed.

Validator - No 'No range defined on numeric parameter' warning for parameters with RTDisplay=false [ID 13217]

From now on, the “No range defined on numeric parameter” warning will no longer appear for parameters of which the RTDisplay setting is set to false.

Validator - No 'Multiple Table Keys with [IDX] in the description' warning if same column is used for both index and display key [ID 13218]

From now on, the “Multiple Table Keys with [IDX] in the description” warning will no longer appear if the same column is used for both index and display key.

Validator - Range of numeric parameters only checked when they are displayed [ID 13851]

Up to now, the validator checked the range of all numeric parameters. Now, it will only check the range of numeric parameters that are displayed.

Fixes

IDE - Problem when importing a protocol [ID 12971]

In some cases, especially when Microsoft Visio Studio was installed in a language other than English, an error occurred when you tried to import a protocol because the “New XML File” template could not be found.

Validator - No 'Unexpected RTDisplay = true' error for trended read parameters without position tag [ID 13221]

In some cases, no “Unexpected RTDisplay = true” error was thrown when the RTDisplay setting of a trended read parameter without position tag was set to true.