General Main Release 10.6.0 CU11 - Preview
Important
We are still working on this release. Some release notes may still be modified or moved to a later release. Check back soon for updates!
Tip
- For release notes related to DataMiner Cube, see DataMiner Cube 10.6.0 CU11.
- For release notes related to the DataMiner web applications, see DataMiner web apps Main Release 10.6.0 CU11.
- For information on how to upgrade DataMiner, see Upgrading a DataMiner Agent.
Prerequisites
Before you upgrade to this DataMiner version:
Make sure version 14.44.35211.0 or higher of the Microsoft Visual C++ x86/x64 redistributables is installed. Otherwise, the upgrade will trigger an automatic reboot of the DMA in order to complete the installation.
The latest version of the redistributables can be downloaded from the Microsoft website:
Make sure all DataMiner Agents in the cluster have been migrated to the BrokerGateway-managed NATS solution.
For detailed information, see Migrating to BrokerGateway.
Changes
Enhancements
No enhancements have been added yet.
Fixes
SLGlobal: Process crash when stopping an asynchronous notification queue [ID 47131]
When SLDMS, SLDataMiner, or SLElement stopped the queue for asynchronous notifications to SLDataMiner, for example during process shutdown, the thread processing that queue could continue running after the queue had been removed. This could cause the process to crash.
From now on, stopping the queue will also stop its processing thread. DataMiner will wait up to 10 seconds for the thread to stop and discard any notifications still in the queue.