General Main Release 10.8.0 – Changes (preview)
Important
We are still working on this release. Some release notes may still be modified or moved to a later release. Check back soon for updates!
Important changes
No important changes have been selected yet.
Changes
Enhancements
SLProtocol: Support for postPonePortInitialisation option removed [ID 46588]
Support for the postPonePortInitialisation communication option has been removed from SLProtocol.
DataMiner upgrade: Upgrade action to configure SAML authentication redirects [ID 46589]
From now on, an upgrade action will automatically add a Set-Cookie header to WebPages/web.config on systems with SAML authentication enabled. This cookie configures web authentication to use redirects instead of an embedded iframe, ensuring compatibility with SAML providers that do not allow their sign-in pages to be displayed in an iframe.
The upgrade action will leave the configuration unchanged if SAML is disabled or the required cookie header is already configured. Existing custom headers, including Set-Cookie headers for other cookies, will be preserved.
DataMiner upgrade: Prerequisite check for Communication Gateway DxM version [ID 46798]
During a DataMiner upgrade, a new prerequisite check will verify the version of the installed Communication Gateway DxM. If the installed version is older than 5.3.5, the upgrade will be blocked.
If the installed Communication Gateway DxM version is older than 4.0.0, the check will also identify the following connectors that use an outdated version of the Skyline.DataMiner.DataSources.OpenConfig.Gnmi.Protocol NuGet package:
- Arista eOS Manager versions older than 1.0.0.5
- CISCO Nexus versions older than 3.0.7.3
To resolve these issues, upgrade Communication Gateway DxM to version 5.3.5 or higher. If any elements use a listed connector, configure them to use a connector version that uses version 6.0.0 or higher of the NuGet package. Remove listed connectors that are not in use.
The additional connector check only detects these known connectors. Make sure no other connectors in use depend on a version of the NuGet package older than 6.0.0.
DataMiner upgrade: Web-only upgrades to 10.7.x or later require at least 10.6.0 [ID 46910]
Web-only upgrade packages for version 10.7.x or later will now be blocked on DataMiner Agents running a server version older than 10.6.0. The error message will indicate this minimum version requirement.
For example, before installing a 10.7.x web-only upgrade on a DataMiner Agent running 10.5.0, you will first have to perform a full upgrade to 10.6.0 or later.
This validation does not affect full DataMiner upgrades.