Table of Contents

MbgNMS 1.1.0

New features

-

Changes

Enhancements

Compatibility with DataMiner 10.2.0.0-11897-CU4 Main Release [ID_33083]

The mbgNMS solution is now compatible with the DataMiner 10.2.0.0-11897-CU4 Main Release.

Compatibility with IDP 1.2.0 [ID_33144]

The mbgNMS solution is now compatible with DataMiner IDP 1.2.0.

Backup options limited to supported backup types [ID_33146]

When you take a backup of a device, now only the supported backup types will be available.

Only relevant device types shown for golden configuration rule configuration [ID_33149]

When you create a golden configuration rule, now only the device types for which backup and restore are possible are shown.

Meinberg LANTIME Modular SyncMon: Parameters with nanoseconds unit now use dynamic units [ID_33150]

Meinberg LANTIME Modular SyncMon parameters that use the nanoseconds unit have now been adjusted to use the dynamic units feature, so that they are converted to a bigger unit in the UI when appropriate.

Meinberg LANTIME Non-Modular SyncMon: Parameters with nanoseconds unit now use dynamic units [ID_33151]

Meinberg LANTIME Non-Modular SyncMon parameters that use the nanoseconds unit have now been adjusted to use the dynamic units feature, so that they are converted to a bigger unit in the UI when appropriate.

Meinberg LANTIME IMS-HPS: Parameters with nanoseconds unit now use dynamic units [ID_33154]

Meinberg LANTIME IMS-HPS parameters that use the nanoseconds unit have now been adjusted to use the dynamic units feature, so that they are converted to a bigger unit in the UI when appropriate.

Compatibility with DataMiner Cube’s black theme [ID_33157]

The Meinberg Network Management System is now compatible with DataMiner Cube's black theme.

Meinberg LANTIME Modular: CPU Load parameter improvements [ID_33158]

In the Meinberg LANTIME Modular connector, the CPU Load parameter now has a range and unit.

Meinberg LANTIME Non-Modular: CPU Load parameter improvements [ID_33159]

In the Meinberg LANTIME Non-Modular connector, the CPU Load parameter now has a range and unit.

Fixes

Incorrect card type shapes in Meinberg LANTIME Modular visual overview [ID_33145]

In the Meinberg LANTIME Modular visual overview, incorrect card type shapes were displayed.

When you selected an entry on the Equipment > Software > Overview page of the Meinberg Element Manager app and clicked Show details, the main page of the app was displayed instead of the detailed information.

Meinberg LANTIME IMS-HPS: Port state displayed incorrectly [ID_33152]

Instead of the correct display value, the Meinberg LANTIME IMS-HPS element showed the value "9" for the port state.

Meinberg Element Manager app: Invalid OS version displayed in inventory summary [ID_33155]

In the inventory summary, if the Device State was not Synchronized, the Model OS would be displayed as N/A.