Harmonic ViBE CP9000
The Harmonic ViBe CP9000 is a contribution encoder that preserves video quality at the front of the broadcast chain by processing uncompressed UHD signals.
About
Version Info
Range | Key Features | Based on | System Impact |
---|---|---|---|
1.0.0.x | - Monitoring. - Configuration of the device. |
- | - |
1.0.1.x [SLC Main] | - Monitoring. - Configuration of the device. |
1.0.0.2 | The display key of the Alarms table and Sub System Info table has changed. |
Product Info
Range | Supported Firmware |
---|---|
1.0.0.x | 2.0-ed-A |
1.0.1.x | 2.0-ed-A |
System Info
Range | DCF Integration | Cassandra Compliant | Linked Components | Exported Components |
---|---|---|---|---|
1.0.0.x | No | Yes | - | - |
1.0.1.x | No | Yes | - | - |
Configuration
Connections
SNMP Main Connection
This connector uses a Simple Network Management Protocol (SNMP) connection and requires the following input during element creation:
SNMP CONNECTION:
- IP address/host: The polling IP or URL of the destination.
- IP port: The IP port of the destination.
SNMP Settings:
- Get community string: The community string used when reading values from the device (default: public).
- Set community string: The community string used when setting values on the device (default: private).
Initialization
No extra configuration is needed.
Redundancy
There is no redundancy defined.
Web Interface
The web interface is only accessible when the client machine has network access to the device.
How to use
General
This page contains product information, such as the System Name, System Description, and Serial Number. It also displays the primary and secondary alarm output status.
HW/SW Info
On this page, you can monitor the Board Info, Software Licenses, and Inventory Info tables.
Alarms
This page contains the following tables:
- Sub System Info: Lists alarms related to one chassis function and one function-encoding channel.
- Alarms: Lists the alarms that are present on the device.
Events
This page contains a table with information regarding events for which the operator should be notified, such as alarm that have been raised or dropped.
IP
On this page, the IP Interfaces table lists all external IP interfaces.
Maintenance
On this page, you can find configurable parameters such as BCAST Status and Transfer Buffer Max Size. Two buttons are available, Reboot and Shutdown, which allow you to execute the corresponding actions on the device.
Presets
This page contains a read-only table listing the previously saved configurations.
Traps