GetActiveAlarmsForElementSortedV2

Use this method to retrieve a specific number of active element alarms along with the alarm cache status.

Available from DataMiner 10.0.7 onwards.

Note

Using this method, you can e.g. request alarms in batches in order to minimize loading time.

Input

Item Format Description
connection String The connection ID. See ConnectApp.
dmaID Integer The DataMiner Agent ID.
elementID Integer The element ID.
groupOn String The field by which to group the alarms. This can be a severity (e.g. “critical”, “major”, etc.) or a relative time string (e.g. “yesterday”, “last week”, etc.)
index Integer The point from which to start returning alarms.
count Integer The number of alarms to be returned.
orderBy String The Alarm Console column(s) by which to order the alarms (separated by semicolons).
Note

The possible groupOn values for this method are usually first retrieved by the GetActiveAlarmPagesForElement method.

Output

Item Format Description
GetActiveAlarmsForElementSortedV2Result Array of DMAAlarm The requested number of active element alarms, sorted as specified, as well as the alarm cache status.