Table of Contents

GetHistoryAlarmsForView

Use this method in order to retrieve the history alarms for a particular view.

Available from DataMiner version 9.5.1 onwards.

Input

Item Format Description
connection String The connection ID. See ConnectApp.
viewID Integer The view ID.
utcStartTime Long integer The start time of the timespan for which alarms should be retrieved, in UTC format (milliseconds since midnight January 1, 1970 GMT).
utcEndTime Long integer The end time of the timespan for which alarms should be retrieved, in UTC format (milliseconds since midnight January 1, 1970 GMT).
filter Array Array of filters limiting which alarms will be retrieved.
filter.IncludeInformationEvents Boolean When true, information events will also be included.
filter.IncludeEntireAlarmTree Boolean When true, all alarms are included. Otherwise, only the top alarms of every alarm tree are returned.
filter.AlarmTypes Array of string Only alarms with an alarm type specified in this array will be returned (default: null).
filter.Severities Array of string Only alarms with a severity specified in this array will be returned (default: null).

Output

Item Format Description
GetHistoryAlarmsForViewResult Array of DMAAlarm The alarms for the specified view and period, limited by the specified filters.